In order to do that you need a chimney with a good draw.
Height of stove pipe above roof for wood burning stove.
For any horizontal through the wall venting system you must have at least 12 inches of vertical rise from the top of the stove not including the flue collar itself or any elbows before connecting a 90 degree elbow piece to turn toward the wall.
I had the roof you see in the photos done in 1991.
How to install wood stove pipe through wall.
For a pitched roof chimney height must be a minimum of 3 feet from where it penetrates the roof or at least 2 feet above the highest roof surface within 10 feet horizontally figure 5.
On flat roofs the chimneys must be at least 3 feet above the roof.
The hot flue gases from your stove need to be able to discharge freely and not present a fire hazard whatever the wind conditions.
Stovepipe differs from chimney systems.
Determine the number of chimney pipe lengths required the chimney must extend at least 3 feet above the highest point where it passes through the roof and be at least 2 foot higher than any part of the building within a horizontal distance of 10 feet figure 2.
The stove pipe wasn t far above the top of the roof and wind blew smoke back into the house.
When installing a wood stove at home it s important to think about the chimney.
There are a few different types of flashing.
I have heard that the top of a wood burning stove pipe needs to be a certain height above the peak of the roof to work properly.
For the next example you have a shorter chimney height.
Installing a wood burning stove means you will need stovepipe.
For 18 feet of run you would have a rise of 72 inches.
Wood stove pipe flashing is incredibly important to protect both your stove and your roof.
Chimney planning step 2.
Installation depends on the route used for the vent pipes.
Vertical horizontal or a combination of both.
Safe and efficient chimney installation depends on the materials of your roof.
If the pipe is farther than 10 feet from the roof.
If the previous calculation results in the required height of 64 inches we can see that the top of the pipe will not rise above the roof peak but would still meet the requirements of the rule.
The top of a chimney pipe must extend at least 2 feet above the peak of the roof if the pipe is within 10 feet of the peak.
That means that it will suck air through from your stove which also helps it to burn.
Flue outlet height uk stove building regs j in document j pages 30 32.